- Delta

Delta MS500.

This membrane is used on both wall and floors with an "air gap" of 5.3 Litres of space per m2. This membrane is used for light water ingress situations, and is also available in a clear version for walls. This aids the selection of good fixing points in the more difficult application i.e. Random stone and friable brickwork.

The sealed DELTA fixing is used to secure System 500, the centre shank of this fixing is also used for subsequent dry lining applications, using a size 12 screw.

Specifications

Cavity drainage membrane for use on walls, floors, vaults and tunnels as a waterproof system. A choice of finishes are available. Can also be used externally for waterproof protection of sub-ground structures.

 

Material

high density polyethylene

Thickness

approx. 0.6mm

Stud Height

approx. 8mm

Roll Size

3.0 x 20m

(With Flat edge of 7cm on one side) 2.4 x 20m

 

2.0 x 20m

Compressive Strength

>250 kN/m

Drainage Capacity

approx. >5 l/s - m

approx. 300 l/min - m

approx. 18,100 l/h - m

Air Volume Between Studs

approx. 5.31 l/m²

Temperature Resistance

-30C to +80C

Chemical Properties

resistant to chemicals, resistant to root penetration, rot proof, neutral towards drinking water

Behaviour In Fire

B2 accord. to DIN 4102, in the case of special requirements possibly B1 accord. to DIN 4102 (test mark PA 2.2087)


Cellars

Basements

Vaults